Basler GigE cameras connect to a computer using a network cable and require proper IP configuration. If a connected camera is not detected, verify the following settings.
For additional troubleshooting, see: Basler camera is not detected by EthoVision.
Open Pylon IP Configurator (Start Menu > Pylon IP Configurator). If a camera appears as not reachable, its IP address likely conflicts with the network port settings.
Use the following static IP configurations for your cameras:
If needed, click the camera in the list, adjust the IP and subnet values, and click Save.
If the camera is still unreachable, assign a matching static IP to the network adapter it's connected to:
Note: Ensure that the third number group (e.g., 200, 201) matches between the camera and adapter. The camera uses .1
while the adapter uses .101
. The Subnet Mask should be 255.255.255.0
.
Click OK and Close to apply the settings. Restart your computer if necessary.